S-ML Series Three-dimensional Wound Core 10KV Oil-immersedTransformer

    S-ML Series Three-dimensional Wound Core 10KV Oil-immersedTransformer

    Triangle s11-mrl-100kvaModel NO.S11-MRLApplicationPower, Electronic, InstrumentPhaseThreeCoreCore-type TransformerCooling MethodOil-immersed Type TransformerWinding TypeMulti-winding TransformerTrademarkEberrySpecificationISO9001, SONCAP, SGS, TUVOriginChinaHS Code85042200001. Rated voltage: 6.3kV, 10kV, 11kV, 13.2kV, 13.8kV, 15kV, 20KV, 22KV, 33KV, 35KV    2. Rated power: 5kva ~ 25000kva    3. Stardard: IEC60076, GB1094-1996    4. Frequency: 50HZ /60HZ    5. Vector group: Dyn11, Yyn0, Ynd11, or others    6. Cooling: ONAN/ ONAF/ OFAF....
  • бөлісу:
  • бізбен хабарласыңы Онлайн сұрау
  • Whatsapp:8613736779975

Triangle s11-mrl-100kva


Model NO.S11-MRL
ApplicationPower, Electronic, Instrument
PhaseThree
CoreCore-type Transformer
Cooling MethodOil-immersed Type Transformer
Winding TypeMulti-winding Transformer
TrademarkEberry
SpecificationISO9001, SONCAP, SGS, TUV
OriginChina
HS Code8504220000


1. Rated voltage: 6.3kV, 10kV, 11kV, 13.2kV, 13.8kV, 15kV, 20KV, 22KV, 33KV, 35KV
 
 2. Rated power: 5kva ~ 25000kva
 
 3. Stardard: IEC60076, GB1094-1996
 
 4. Frequency: 50HZ /60HZ
 
 5. Vector group: Dyn11, Yyn0, Ynd11, or others
 
 6. Cooling: ONAN/ ONAF/ OFAF
 
 7. Tap changer: 3 levels; 5 levels; 7 levels; 13 levels; 17 levels
 
 8. Rating plate: : Yes (JSM brand or Customer brand)
 
 9. Corrugated refrigeration panels: Yes ( Four sides of the transformer shell)
 
 10. Parts: 1)Oil draining valve 2)Oil level indicator 3)Thermometer
 
 About Our Company:
 
 1.26 years' manufacturing experience with three subsidiaries
 
 2. Won tenders aboard
 
 3. IEC 60076 & ISO certificate
 
 4. OEM / ODM
 
 5. Competitive price with 100% Cu winding
 
 6. Production capacity: 10, 000, 000 kVA per year


REFERENCES ISO 1461: Hot dip galvanized coatings on fabricated iron and steel articles Specifications and test methods. IEC 60076: Power transformers. IEC 60044: Instrument transformers. IEC 60296: Specification for unused mineral insulating oil for transformers and switchgear. IEC 60354: Loading guide for oil immersed power transformers. IEC 60214: Tap-changers - Part 1: Performance requirements and test methods, Part 2: Application guide. IEC 60512: Connectors for electronic equipment. ROUTINE TEST to IEC 60076 (to be done during acceptance testing at factory) Measurement of winding resistance Ratio test Vector group Separate source voltage withstand test Induced over-voltage Insulation resistance Oil leakage test on fully assembled transformer for 12 hours Measurement of impedance voltage Magnetic balance Measurement of no-load loss and current Measurement of load loss (at normal & extreme taps) Tests on on-load tap-changer Tests on on-load tap-changer remote control panel Efficiency at 50%, 75%, 100% loading at unity p. F and rated terminal voltage (Corrected to 75C) Lightning impulse withstand test
 
 Type Tests to IEC 60076 (to be done during acceptance testing at factory) Temperature rise test To be performed on one unit during acceptance testing. Lightning Impulse Withstand Test is already listed under Routine Tests as per IEC 60076.



онлайн хабарлама

Жарамды электрондық пошта мекенжайын толтырыңыз
тексеру коды Бос болуы мүмкін емес

қосымша тауарлар

Әзірге іздеу нәтижелері жоқ!
Contact Us

Phone: +8613736779975

E-mail: sales@vcbbreaker.com

Address: 66 Punan Road, Yueqing Economic Development Zone, Zhejiang, China

Авторлық құқық © 2025 Yangmei Electrish Group Барлық құқықтар қорғалған

Сайт картасы

Бұл веб-сайт біздің веб-сайтта ең жақсы тәжірибе алуыңызды қамтамасыз ету үшін cookie файлдарын пайдаланады.

Қабылдау бас тарту